Maintenance
Description
item No.
2AV/X
1-4-94
1-4
U344 Setting preheat/energy saver mode
Description
Changes the control for preheat/energy saver mode.
Purpose
According to user request, selects which has priority, the recovery time from preheat or energy saver.
Method
Press the start key.
Setting
1. Select control mode using the zoom +/– keys.
Display Control in preheat mode
InS (instant ready) Without decreasing the fixing control temperature, the display
on the operation panel is turned off.
ESr (energy star) The fixing control temperature is set at 70°C/158°F. The
copier is forcibly stabilized 30 s after exiting preheat/energy
saver mode.
Prh (priority to recovery time) The fixing control temperature is set at 130°C/266°F.
Initial setting: Energy star
2. Press the start key. The setting is set, and the indication for selecting a maintenance item No. appears.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The indication for
selecting a maintenance item No. appears.
U345 Setting the value for maintenance due indication
Description
Sets when to indicate that the time for maintenance is about to be reached, by setting the number of copies that
can be made before the current maintenance cycle ends.
When the difference between the number of copies of the maintenance cycle and that of the maintenance
count reaches the set value, the maintenance indicator flashes.
Purpose
To change the time to display the maintenance due indication.
Method
Press the start key. The current setting is displayed.
Setting
1. Select the item by lighting a copy exposure indicator using the copy exposure adjustment keys.
Copy exposure indicator Description Setting range Initial setting
Exp. 1 First digit 0 to 9 0
Exp. 2 Last 3 digits 000 to 999 000
2. Change the setting value using the numeric or zoom +/– keys.
3. Press the start key. The setting is set, and the indication for selecting a maintenance item No. appears.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The indication for
selecting a maintenance item No. appears.