2AV/X
2-1-16
2-1
Start key
DM
RCL
RSW
TC REM
418 ms
474 ms
Timing chart 2-1-5 Operation of transfer
a: 418 ms after the registration clutch (RCL) turns on to start secondary paper feed, transfer charging (TC REM) starts.
b: 474 ms after the trailing edge of the paper turns the registration switch (RSW) off, transfer charging (TC REM) ends.