2AV/X
1-5-27
Problem Causes Check procedures/corrective measures
1-5
*1: Optional for 15 cpm copier. *2: For 20 cpm copier only. *3: Optional for 220-240 V specifications of 15 cpm copier.
*4: Optional for both 20 cpm and 15 cpm copiers.
(16)
The exposure lamp
does not turn on.
(17)
The exposure lamp
does not turn off.
(18)
The fixing heater
does not turn on
(C610).
(19)
The fixing heater
does not turn off.
(20)
Main charging is not
performed (C510).
(21)
Transfer charging is
not performed.
(22)
No developing bias
is output.
(23)
The original size is
not detected.
Poor contact in the
exposure lamp connector
terminals.
Defective inverter PCB.
Defective inverter PCB.
Broken wire in fixing
heater.
Fixing unit thermostat
triggered.
Broken fixing unit
thermistor wire.
Dirty sensor part of the
fixing unit thermistor.
Broken main charger wire.
Leaking main charger
housing.
Poor contact in the high-
voltage transformer PCB
connector terminals.
Defective main PCB.
Defective high- voltage
transformer PCB .
Poor contact in the high-
voltage transformer PCB
connector terminals.
Defective main PCB.
Defective high-voltage
transformer PCB .
Poor contact in the
developing bias wire.
Poor contact in the high-
voltage transformer PCB
connector terminals.
Defective high-voltage
transformer PCB .
Defective original
detection switch*
3
.
Reinsert the connector. Also check for continuity within the
connector cable. If none, remedy or replace the cable.
If the exposure lamp does not turn on when CN24-1 and CN24-2
on the inverter PCB are held low, replace the inverter PCB.
If the exposure lamp does not turn off when CN24-1 and CN24-2
on the inverter PCB are held high, replace the inverter PCB.
Check for continuity across the heater. If none, replace the
heater.
Check for continuity across the thermostat. If none, remove the
cause and replace the thermostat.
Measure the resistance. If it is ∞ Ω, replace the fixing unit
thermistor.
Check visually and clean the thermistor sensor parts.
See page 1-5-18.
See page 1-5-18.
Check the developing bias wire. If there is any problem, replace
it.
Reinsert the connector. Also check for continuity within the
connector cable. If none, remedy or replace the cable.
Check if the developing bias is output when CN1-3 on the high-
voltage transformer PCB goes low while maintenance item U030
is run. If not, replace the high-voltage transformer PCB.
Check if CN25-2 on the main PCB goes low when the original
detection switch*
3
is turned on and off. If not, replace the original
detection switch*
3
.
Zobrazit stránku 177