2AV/X
1-5-25
1-5
*1: Optional for 15 cpm copier. *2: For 20 cpm copier only. *3: Optional for 220-240 V specifications of 15 cpm copier.
*4: Optional for both 20 cpm and 15 cpm copiers.
1-5-4 Electrical problems
Problem Causes Check procedures/corrective measures
(1)
The machine does
not operate when
the main switch is
turned on.
(2)
The drive motor
does not operate
(C200).
(3)
The scanner motor
does not operate.
(4)
The toner feed
motor does not
operate.
(5)
Cooling fan motor 1
does not operate.
(6)
Cooling fan motor 2
does not operate.
No electricity at the power
outlet.
The power cord is not
plugged in properly.
The front cover, paper
conveying unit and/or
lower drawer left cover*
1
are/is not closed
completely.
Broken power cord.
Defective main switch.
Blown fuse in the power
source PCB.
Defective safety switch 1,
2 or 3*
1
.
Defective power source
PCB.
Poor contact in the drive
motor connector terminals.
Broken drive motor gear.
Defective drive motor.
Broken scanner motor coil.
Poor contact in the
scanner motor connector
terminals.
Broken toner feed motor
coil.
Poor contact in the toner
feed motor connector
terminals.
Broken cooling fan motor 1
coil.
Poor contact in the cooling
fan motor 1 connector
terminals.
Broken cooling fan motor 2
coil.
Poor contact in the cooling
fan motor 2 connector
terminals.
Measure the input voltage.
Check the contact between the power plug and the outlet.
Check the front cover, paper conveying unit and lower drawer
left cover*
1
.
Check for continuity. If none, replace the cord.
Check for continuity across the contacts. If none, replace the
main switch.
Check for continuity. If none, remove the cause of blowing and
replace the fuse.
Check for continuity across the contacts of each switch. If none,
replace the switch.
With AC present, check for 3.3 V DC at CN3-9 on the power
source PCB, 5 V DC at CN3-5 and CN3-6, 12 V DC at CN4-3
and 24 V DC at CN3-1 and CN3-2. If none, replace the power
source PCB.
Reinsert the connector. Also check for continuity within the
connector cable. If none, remedy or replace the cable.
Check visually and replace the drive motor if necessary.
Run maintenance item U030 and check if the drive motor
operates when CN12-16 on the main PCB goes low. If not,
replace the drive motor.
Check for continuity across the coil. If none, replace the scanner
motor.
Reinsert the connector. Also check for continuity within the
connector cable. If none, remedy or replace the cable.
Check for continuity across the coil. If none, replace the toner
feed motor.
Reinsert the connector. Also check for continuity within the
connector cable. If none, repair or replace the cable.
Check for continuity across the coil. If none, replace cooling fan
motor 1.
Reinsert the connector. Also check for continuity within the
connector cable. If none, repair or replace the cable.
Check for continuity across the coil. If none, replace cooling fan
motor 2.
Reinsert the connector. Also check for continuity within the
connector cable. If none, repair or replace the cable.