Utax CD 1015 Servisní příručka Strana 136

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 296
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 135
Maintenance
Description
item No.
2AV/X
1-4-88
1-4
U253 Switching between double and single counts
Description
Switches the count system for the total counter and other counters.
Purpose
According to user (copy service provider) request, select if A3/11" × 17" paper is to be counted as one sheet
(single count) or two sheets (double count).
Method
Press the start key.
Setting
1. Select double or single count using the zoom +/– keys.
Display Description
d-C Double count for A3/11" × 17" paper only
S-C Single count for all size paper
Initial setting: Double count
2. Press the start key. The setting is set, and the indication for selecting a maintenance item No. appears.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The indication for
selecting a maintenance item No. appears.
U254 Turning auto start function on/off
Description
Selects if the auto start function is turned on.
Purpose
Normally no change is necessary. If incorrect operation occurs, turn the function off: this may solve the
problem.
Method
Press the start key.
Setting
1. Select either “on” or “oFF” using the zoom +/– keys.
Display Description
on Auto start function on
oFF Auto start function off
Initial setting: on
2. Press the start key. The setting is set, and the indication for selecting a maintenance item No. appears.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The indication for
selecting a maintenance item No. appears.