Utax CD 1015 Servisní příručka Strana 167

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 296
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 166
2AV/X
1-5-16
Code Contents
Remarks
Causes Check procedures/corrective measures
1-5
*: Optional **: Optional for the 15 cpm copier only.
C731
C740
C817
C818
C819
C821
Short-circuited external temperature
thermistor
The input voltage is below 0.5 V.
Image formation unit connector
insertion problem
Absence of the image formation unit
is detected continuously for 1500 ms
while there is no error on the copier.
Finisher* front side registration
motor problem
Finisher* rear side registration
motor problem
Finisher* trailing edge registration
motor problem
Finisher* stapler motor problem
Poor contact of
the humidity
sensor PCB
connector
terminals.
Defective external
temperature
thermistor.
Image formation
unit connector
inserted
incorrectly.
Defective image
formation unit
connector.
A problem is
detected with the
front side
registration motor.
A problem is
detected with the
rear side
registration motor.
A problem is
detected with the
trailing edge
registration motor.
A problem is
detected with the
stapler motor.
Reinsert the connector. Also check for
continuity within the connector cable. If
none, repair or replace the cable.
Replace the humidity sensor PCB.
Reinsert the image formation unit
connector if necessary.
Replace the image formation unit.
See the finisher service manual.
See the finisher service manual.
See the finisher service manual.
See the finisher service manual.
Zobrazit stránku 166
1 2 ... 162 163 164 165 166 167 168 169 170 171 172 ... 295 296

Komentáře k této Příručce

Žádné komentáře